Faxitron - BioVision Surgical Specimen Radiography System | Faxitron Bioptics LLC

BioVision

The Faxitron BioVision provides immediate verification of excised breast tissue margins. The BioVision raises the standard of care to new heights for patients undergoing surgical excision or biopsy procedures. Save time in the OR by x-raying the specimen intra-operatively. The image can be sent to mammography via PACS while the specimen is sent directly to pathology. 

  • Instant confirmation of a successful biopsy procedure
  • No additional X-ray shielding required
  • No specialized X-ray knowledge needed to operate
  • Self-reimbursing with saved OR time
  • Small footprint to minimize intrusion in point of care environment
  • All hardware components bolted in/on mobile cart to ensure hardware integrity and personnel safety both during and after transport
  • Keyboard with single, continuous surface for easy cleaning and disinfection
  • Plugs into any A/C outlet or can operate stand-alone for more than 3 hours on battery backup
  • Entire system powered on with single button for ease-of-use
  • No re-calibration or restarting required after transport
  • Magnification shelf with field of view guides and automatic position detection provides for geometric magnification with accurate measurements at any level
  • Transparent specimen window ensures proper alignment
  • One button operation with Automatic Exposure Control (AEC) for optimal image quality
  • AEC optimized for breast excisions and core biopsies
  • Leading-edge Image Processing software including Peripheral Equalization and Calcification enhancement
  • Images instantaneously displayed on 24'' high resolution 3.7 MP monitor
  • DICOM compliant software with efficient access to modality work list and PACS Store and Print options
  • Ability to send multiple annotated images to PACS at a touch of a button
  • Automatic calibration and self-diagnostic capability
  • Remote diagnostic and support over the Web

Specimen Imaging Area

  • 10cm x 15cm (4" x 6")
Spatial resolution 10lp/mm (48µm), contact mode
Energy range20-40 kV
Tube current1.5mA
Focal spot size, nominal50µm
Geometric magnification1.4X , 2X (up to 20lp/mm)
Window filtration0.125mm Be, molybdenum source
DICOM InterfaceStore, Annotate, Print & Modality Work List
Power120 VAC 600 W Max / 240 VAC 720 W Max
Dimensions22" W x 23" D x 67" H (56 cm x 57 cm x 170 cm)
Internal Chamber 11" W x 11.5" D x 14" H (28 cm x 29 xm x 36 cm)
Weight200 lbs. (90 kg)